SCADAfeathery for Modbus Application icon

SCADAfeathery for Modbus V

4.8 MB / 10+ Downloads / Rating 5.0 - 1 reviews


See previous versions

SCADAfeathery for Modbus, developed and published by AutomationServices, has released its latest version, V, on 2023-02-12. This app falls under the Productivity category on the Google Play Store and has achieved over 1000 installs. It currently holds an overall rating of 5.0, based on 1 reviews.

SCADAfeathery for Modbus APK available on this page is compatible with all Android devices that meet the required specifications (Android). It can also be installed on PC and Mac using an Android emulator such as Bluestacks, LDPlayer, and others.

Read More

App Screenshot

App Screenshot

App Details

Package name: com.automationservices.scadafeathery

Updated: 2 years ago

Developer Name: AutomationServices

Category: Productivity

New features: Show more

App Permissions: Show more

Installation Instructions

This article outlines two straightforward methods for installing SCADAfeathery for Modbus on PC Windows and Mac.

Using BlueStacks

  1. Download the APK/XAPK file from this page.
  2. Install BlueStacks by visiting http://bluestacks.com.
  3. Open the APK/XAPK file by double-clicking it. This action will launch BlueStacks and begin the application's installation. If the APK file does not automatically open with BlueStacks, right-click on it and select 'Open with...', then navigate to BlueStacks. Alternatively, you can drag-and-drop the APK file onto the BlueStacks home screen.
  4. Wait a few seconds for the installation to complete. Once done, the installed app will appear on the BlueStacks home screen. Click its icon to start using the application.

Using LDPlayer

  1. Download and install LDPlayer from https://www.ldplayer.net.
  2. Drag the APK/XAPK file directly into LDPlayer.

If you have any questions, please don't hesitate to contact us.

Previous Versions

SCADAfeathery for Modbus V
2023-02-12 / 4.8 MB / Android

About this app

You have a Modbus device and want to visualize it by a few easy steps?
Are you an owner of WAGO (P-)FC series 750/758?
Are your writing CoDeSys 2.3 programms on WAGO-devices and want to
see the calculation results on your android device?
Then this application is that what you are looking for.
After only 3 steps the definition of the visualization is complete:
1) Define your Modbus network.
2) Create data points.
3) Define the representation of the data points

You can define any number of devices on the network.
The devices (called network services) are stored in the application,
and can be used later.
For each device (network service), you can assign its data points.
The definition of a datapoint consists of the following parameters:
- Designation of the datapoint

- Datatype of the datapoint (based on IEC61131-Datatypes)
- Datatype STRING requiers the length in bytes additionaly
- Read-Defintion: FC-Code (FC1, FC2, FC3, FC4)
- Read-Definition: modbus address (register or coil, depends on FC-Code)
- Read-Definition: bit offset, within the addressed modbus register or coil
- Write-Defintion: FC-Code (FC5, FC6, FC15, FC16)
- Write-Definition: modbus address (register or coil, depends on FC-Code)
- Write-Definition: bit offset, within the addressed modbus register or coil

For WAGO-Devices this parameters are filled out automaticaly.

Each data point can be visualized by (at the moment) 4 presentation items:
+ Textbox
+ Slider (0..100)
+ Switch
+ XY-Plot
Your are able to scale the values by the linear polynom (f(x)=m*x+b).
You can define min/max-ranges, that are monitored at the runtime.
There is a constant monitoring of the data point availability , you will be notified
if the datapoint is not accessable anymore.


Modbus-communication

The communication is possible through Wifi and 3G/4G- Networks.
Following modbus function codes are supported:
FC1, FC2, FC3, FC4,FC5,FC6,FC15,FC16.
An real-time algorithm used for communication task guarantees that the calculated
cycle-time for each communication-job will be kept.
The cycle-time is linearly proportional to the number of datapoints within the perspective.



Special features for WAGO-Devices

This appliation contains a database with all at the moment existing WAGO-Controllers and Couplers
of the series 750/758. There is also modbus process image data about all terminals of the series 750/753.

You have defined your WAGO node already as network service?
Then mark the discovered devices as WAGO device and scan the node.
The connected terminals will be recognized and the full process image for modbus will be stored.
Now you no longer have to calculate the address of the terminal in the process image.
Just select the terminal and the channel of the terminal from the node description and make it to
a data point.
Do you have a PFC (programmable WAGO coupler)? Then it is possible to you to define a datapoint just by
entereing of the IEC61131-address. Just enter the %I, %Q, %M address of your programm variable and the application
converts this information into accoridn modbus-address on the network.
Hint: Consider the PI-Assignment-Setting from CoDeSys if you want the write-access to kbus-terminals.

New features

Bugfix for dark mode

App Permissions

Allows applications to open network sockets.
Allows applications to enter Wi-Fi Multicast mode.